Waveguide Arc Detectors

Standard Arc Detector Specifications

Input Power:

15 volts

Pressure Sealed to:

30 psi

Output:

TTL

Response Time:

less than 10 米sec

Arc Detector Options:

A -
Input Power at Pin A is +28V

B - Latching Capability.  Output is TTL unless otherwise specified.  The armed state is TTL 1 (+5V).  Fired State is TTL 0.  After being triggered by an arc, the latching circuit must be reset to return to the armed state.  This is accomplished by bringing Pin C to TTL momentarily, then returned to TTL 0.
For option BB , Pin C is at ground in the armed state.  To reset, Pin C is momentarily lifted off ground (open circuit) then returned to ground.

C - Self test by means of an LED built in to the Arc Detector.  Power to illuminate the LED is applied to Pin B.  Five volts is applied to Pin B.  Current required is 5 to 10 ma.

D - Output voltage +14 to + 17 volts.  This option requires choosing option A, 28 volts input.  The armed voltage is +14 to +17 volts.  The fired voltage is 1 to 2 volts.

For any of the options shown above add the appropriate letter to the end of the model number.  It is possible to add more than one option.
Example P/N:   137每ARCE每A每2每2 becomes: 137每ARCE每A每2每2/AB when options A & B are desired.

 

Additionally, Bi-Directional Arc Detectors are also available.  These can be supplied on 90o E or H bends or on straight sections of waveguide.  The same options as on the units listed are available.

Arc Detectors

WG Size

Freq. (GHz)

VSWR
(max)

Insertion Loss
(max)

Peak Pow
(max)

Model #

Outline
Drawing

WR284

2.60 - 3.95

1.10

0.05

1 MW

284-ARCE-A-6-6

Dwg

WR229

3.30 - 4.90

1.10

0.05

900 KW

229-ARCE-A-2-2

Dwg

WR187

3.95 - 5.85

1.10

0.05

800 KW

187-ARCE-A-6-6

Dwg

WR159

4.09 - 7.05

1.10

0.05

700 KW

159-ARCE-A-2-2

Dwg

WR137

5.85 - 8.20

1.10

0.05

600 KW

137-ARCE-A-2-2

Dwg

WR112

7.05 - 10.0

1.10

0.05

500 KW

112-ARCE-A-6-6

Dwg

WR90

8.20 - 12.4

1.10

0.05

400 KW

90-ARCE-A-6-6

Dwg

WR75

10.0 - 15.0

1.10

0.05

325 KW

75-ARCE-A-6-6

Dwg

WR62

12.4 - 18.0

1.10

0.05

250 KW

62-ARCE-A-6-6

Dwg

WR51

15.0 - 22.0

1.10

0.05

200 KW

51-ARCE-A-6-6

Dwg

WR42

18.0 - 26.5

1.10

0.05

150 KW

42-ARCE-A-6-6

Dwg

WR34

22.0 - 33.0

1.10

0.05

100 KW

34-ARCE-A-6-6

Dwg

WR28

26.5 - 40.0

1.10

0.05

50 KW

28-ARCE-A-6-6

Dwg

The Model numbers listed above are the most common model numbers for material and flanges, however, these models can easily be altered to accommodate customer needs by following the Model # code system.  See ATM Flange page for more information on flanges.

Ordering Information

                         

Example: P/N:   284每ARCE每A每6每6B is:
WR284 Waveguide  - Aluminum  每  Cover Flange 每 Cover Flange 每 Option B