RMME |
|
8-12-20 inverter contacts 10A |
| DC coil control |
Nominal voltage (Um) Woking
voltage Consumption
|
6 to 440 80% ~ 120% 8 contacts -
3W 12 and 20 contacts - 6W
|
| AC coil control |
Nominal voltage Woking
voltage Consumption
|
6 to 440 85% ~ 110% 8 contacts -
11,5VA 12 and 20 contacts - 25VA
|
| Contacts |
Number and type Max cut-out Max transient
current Pressure of make contact Pressure of break
contact Make time Un dc
Make / break Un
ac
Break time Un dc
Make / break Un
ac
|
8-12-20 changeover 10A continuous 40A for 1
second
40 ms for 8 contacts 37 ms for 12
contacts 35 ms for 20 contacts 10 ms for 8
contacts 10 ms for 12 contacts 10 ms for 20
contacts 64 ms for 8 contacts 70 ms for 12
contacts 40 ms for 20 contacts 30 ms for 8
contacts 30 ms for 12 contacts 35 ms for 20
contacts |
| Mechanics and environment
|
Coil-contact dielectric strengt Contact- contact
dielectric strengt Isolation resistence Mechanical
life Environmental conditions (tropicalised
version) Vibration resistance Shock resistence
Weight
Options Accessories
|
2KV for 1 min. 2KV for 1
min.
>10000Mohm to 500VDC 20.000.000
operations
8 contacts - 450gr. 12
contacts - 740gr. 20 contacts - 1180gr. |
|
|