menu
Products
Integration of RF, optoelectronic, embedded, automation and software technologies to provide dedicated equipment and solutions
AFX100 Series Test Fixture
AFX100 series fixture is a measuring fixture with an adjustable sliding table spacing, which is mainly used to measure the high frequency S parameters of the element. Can be equipped with TRL calibration parts, only a pair of coaxial connectors, can reduce the additional error to a minimum, high measurement accuracy, suitable for precision measurement of components.
After the tested part is put into the stage, the stage is put into the main body of the fixture. The rotation of the screw pushes the sliding stage to contact and lift the stage to connect with the coaxial connector to complete the signal connection.
The minimum length of the measurable device is 3.3mm and the maximum length is 49.5mm. The maximum pin position deviation of the measurable asymmetric pin device is 8mm.

· High test frequency: DC-50GHz
· Typical power: 37dBm @ 8Ghz

· RF active passive S-parameter small batch delivery test · RF active passive S-parameter precision test ·Precision Measurement of High Frequency Parameters of RF Passive Devices

Equipment Specifications
AFX100 Series Test Fixture
AFX100 series fixture is a measuring fixture with an adjustable sliding table spacing, which is mainly used to measure the high frequency S parameters of the element. Can be equipped with TRL calibration parts, only a pair of coaxial connectors, can reduce the additional error to a minimum, high measurement accuracy, suitable for precision measurement of components.
After the tested part is put into the stage, the stage is put into the main body of the fixture. The rotation of the screw pushes the sliding stage to contact and lift the stage to connect with the coaxial connector to complete the signal connection.
The minimum length of the measurable device is 3.3mm and the maximum length is 49.5mm. The maximum pin position deviation of the measurable asymmetric pin device is 8mm.

· High test frequency: DC-50GHz
· Typical power: 37dBm @ 8Ghz

· RF active passive S-parameter small batch delivery test · RF active passive S-parameter precision test ·Precision Measurement of High Frequency Parameters of RF Passive Devices

Equipment Specifications
| Master fixture configuration | |||||||
| Working frequency band | Coaxial interface | Composition | Performance | ||||
| Required | Optional | Standing wave (straight-through) | |||||
| DC-26.5GHz | 2.92/f | Subject | carrier | TRL Calibration Kit | 1.2 | ||
| DC-40GHz | 2.92/f(2.4mm/f) | Subject | carrier | TRL Calibration Kit | 1.4 | ||
| DC-50GHz | 2.4mm/f | Subject | carrier | TRL Calibration Kit | 1.5 | ||
| TRL Calibrator Configuration | |||||||
| Working frequency band | Load | Delayed line | Reflector | through line | |||
| Line1 | Line2 | Line3 | Line4 | Short | Thru | ||
| DC-26.5GHz | 1 | 1 | 1 | 1 | - | 1 | 1 |
| DC-40GHz | 1 | 1 | 1 | 1 | - | 1 | 1 |
| DC-50GHz | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| Optional test stage | |||||||
| Working frequency band | SMD Chip Component Package (Inch) | Ceramic, microstrip circuit substrate package | |||||
| DC-26.5GHz | 0201-1206 | Length: 3.3-49mm | |||||
| DC-40GHz | 0201-0805 | Length: 3.3-49mm | |||||
| DC-50GHz | 0201-0805 | Length: 3.3-49mm | |||||
-
Address: Floor 10, Building 17, District 18, Fengtai District Headquarters Base, Beijing
Zip Code: 100070
Telephone:010-63718360
Email:sales@aumiwalker.com
Company website:www.aumiwalker.com
Enterprise WeChat
Taobao Store